Further Discounts may be available. Call us for details.
We Ship Worldwide

Model: CENTURION II - DISCONTINUED

NewMar Centurion II Power System - DISCONTINUED
Contact Information

NewMar

NewMar Centurion II Power System - DISCONTINUED

NewMar Centurion II Power System
Newmar Model: Centurion II

More information on NewMar Centurion II Power System:
NewMar Centurion II Power System Brochure

Incredible Functionality, Flexibility, and Scalability in a 2 RU, 1.0 to 6.0 Kw DC Power System
• 19", 2U rackmount shelf with integrated power distribution
• 90-250 VAC input, Power Factor Corrected
• 3 power bays accept 1000 or 2000 watt modular rectifiers
• 111 amp, 6000 watt total max. output capacity, (74 Amp, 4000 Watt, N+1) @ - 48 VDC
• Output temperature compensated for precise battery charging
• 16 DC circuit breaker distribution capacity, with tripped breaker alarm
• Master disconnect breakers for two battery banks, with tripped breaker alarm
• Controller with digital display of system parameters with TCP/IP interface and
SNMP monitoring/logging
• Alarm contacts monitor major system functions
• Low voltage disconnect built in
• Easily configures to meet site power requirements

Complete system design and integration by Newmar to your application parameters: Rectifier configuration, installation of distribution circuit breakers, and configuration of alarms and monitors. Assembly in a relay rack with batteries and wiring also available. Let us submit a proposal on your next project.

NewMar Centurion II Power System Specifications:
System Power Configurations @ 48V*
Watts Per Rectifier # of Rectifiers Installed
1 2 3
2000 37A (2000W) 74A (4000W) 111A (6000W)
1000 18A (1000W) 36A (2000W) 54A (3000W)
System Power Configurations @ 24V*
2000 37A (2000W) 74A (4000W) 111A (6000W)
* @ 230 VAC input, 2Kw: derate 41% @ 110 VAC input; 1Kw: derate 33% @ 110 VAC input

NewMar Centurion II Power System AC Input:
Nominal: 230V
Voltage Range: 90-300V (derate @ 115 input)
Frequency Range: 45-65 Hz
Power Factor: >0.99
Efficiency: >94% (from 30-95% output power)

NewMar Centurion II Power System DC Output:
Voltage -48 volt +24 volt
Output Ratings: Constant power output
from 48V to 58V
Constant power output from
24V to 29V
Nominal Voltage: 48V 24V
Rated Voltage: 58V 29V

NewMar Centurion II Power System Power:
Rated maximum System Output Power: 6000W @ -48V, 3000 watts @ 24 volts
Polarity: Positive earth. 48 volt, negative earth 24 volt
Individual Rectifier Power: (24 and 48 volt) 1000 watt 2000 watt
Amperage @ 230 vac in 18 37
Amperage @ 115 vac in 12 21


NewMar Centurion II Power System DC Distribution:
Load: 16 breaker positon capacity, available amperages (specify) 6A, 10A, 20A, 30 amp, with
tripped breaker alarm
Battery: 2 x 100A battery circuit breakers.
Breaker Fail Detection: Electronic fail detection on both load and battery. Breakers
Low Voltage Battery Disconnect: 125A battery LVD installed standard, with disconnect alarm

NewMar Centurion II Power System Monitoring & Control:
Monitors all power system conditions including DC voltage, rectifier current, battery current, battery temperature, and distribution failure. Visual notification of alarm conditions by LED's and a 4 line x 16 character alpha numeric display mounted on the front panel, with remote notification being enabled by relay contacts, RS232 or TCP/IP (using SNMP). It has a built-in web based configurator allowing setup of system parameters using a web browser and utilizes a USB communications port which allows for local monitoring of
system operations as well as easy downloading of configuration files for multiple site installations.

General NewMar Centurion II Power System Specifications:
Protection:
Current Limit: Adjustable to 50-100% of maximum rated current.
Over Temperature: Automatic current reduction, backup shutdown protection.
Polarity Reversal: Output fuse with crowbar diode.
Over Voltage: Adjustable limit.
Input Voltage: Auto shutdown, auto restart when correct voltage restored.
Input Inrush: <2x maximum input current.
Input Fuses: In phase and neutral.

NewMar Centurion II Power System Technical Characteristics:
Noise: Ripple <100Hz: <1mV rms unweighted
Voice band 100Hz-5KHz: <1mV rms psophometric
Wide band 5kHz-1MHz: <5mV rms unweighted
Peak to Peak 0-20MHz: <100mV peak to peak
Isolation: Input to Output: 4000V DC.
Input to Chassis: 3500V DC (VDR to chassis removed)
Output to Chassis: 2100V DC
Regulation: Line = ±0.1%, Load = ±0.5% (no load to full load)

NewMar Centurion II Power System Mechanical Specifications:
Shelf: Dimensions / 19" W x 3.5" H x 15.35" D /
Weight: 19.84 Lbs. (excluding rectifier modules)
Rectifers: Dimensions / 4.25" W x 2.75" W x 11.1" D /
Weight: 3.15 Lbs
Cooling: Forced cooled

NewMar Centurion II Power System Environmental Parameters
Ambient Temperature: Nominal: 25+/-5º C
Range: -10º C to +70º C (maximum output power is derated above +50º C)
Humidity: 5-95% RH (non-condensing)
Altitude: <8,202 ft., De-rate maximum ambient temperature by 4º C per 3,280 ft. above sea level.

NewMar Centurion II Power System Certifications and Compliances:
Safety: EN60950
Electrostatic Discharge: CISPR24
Radiated Radio Freq: CISPR22
AC Harmonics: EN61000-3-2
AC Flicker & Fluctuation: EN61000-3-3
Other: CE & RoHS compliant
NewMar Centurion II Power System Newmar Model: Centurion II More information on NewMar Centurion II Power System: ● NewMar Centurion II Power System Brochure Incredible Functionality, Flexibility, and Scalability in a 2 RU, 1.0 to 6.0 Kw DC Power System • 19", 2U rackmount shelf with integrated power distribution • 90-250 VAC input, Power Factor Corrected • 3 power bays accept 1000 or 2000 watt modular rectifiers • 111 amp, 6000 watt total max. output capacity,...